Test Method
|
Title
|
ANSI Z97.1
|
Safety Performance Specifications and Methods of Test for Safety Glazing Materials used in Buildings
|
ASTM C 1048
|
Standard Specification for Heat-Treated Flat Glass—Kind HS, Kind FT Coated and Uncoated Glass
|
ASTM C 1199
|
Thermal Transmittance of Fenestration Systems Using Hot Box Methods
|
ASTM C 1201
|
Structural Performance of Exterior Dimension Stone Cladding Systems by Uniform Static Air Pressure Difference
|
ASTM C 1382
|
Test Method for Determining Tensile Adhesion Properties of Sealants When Used in Exterior Insulation and Finish Systems (EIFS)
|
ASTM C 236
|
Steady State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box
|
ASTM D 2105
|
Standard Test Method for Longitudinal Tensile Properties of Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Tube
|
ASTM D 2565
|
Standard Practice for Xenon Arc Exposure of Plastics Intended for Outdoor Applications
|
ASTM D 4073
|
Standard Test Method for Tensile-Tear Strength of Bituminous Roofing Membranes
|
ASTM D 4099
|
Windows, Poly[Vinyl Chloride] (PVC) Prime Windows/Sliding Glass Doors
|
ASTM D 4798
|
Standard Test Method for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon-Arc Method)
|
ASTM D 638
|
Standard Test Method for Tensile Properties of Plastics
|
ASTM D 897
|
Standard Test Method for Tensile Properties of Adhesive Bonds
|
ASTM E 1017
|
Generic Performance Requirements for Exterior Residential Window Assemblies
|
ASTM E 1105
|
Field Determination of Water Penetration of Installed Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference
|
ASTM E 1155
|
Floor, Determining FF Floor Flatness and FL Floor Levelness Numbers
|
ASTM E 1186
|
Air Leakage Site Detection in Building Envelopes
|
ASTM E 1233
|
Structural Performance of Exterior Doors by Cyclic Static Air Pressure Differential
|
ASTM E 1423
|
Steady State Thermal Transmittance of Fenestration Systems
|
ASTM E 1424
|
Air Leakage Resistance at a Specified Air Pressure and Temperature Differential
|
ASTM E 1514
|
Structural Standing Seam Steel Roof Panel Systems
|
ASTM E 1554
|
Determining External Air Leakage of Air Distribution Systems by Fan Depressurization
|
ASTM E 1592
|
Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference
|
ASTM E 1646
|
Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
|
ASTM E 1677
|
Air Retarder (AR) Material or System for Low-Rise Framed Building Walls
|
ASTM E 1886
|
Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
|
ASTM E 196
|
Gravity Load Testing of Floors and Flat Roofs
|
ASTM E 283
|
Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen
|
ASTM E 330
|
Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference
|
ASTM E 331
|
Water Penetration of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference
|
ASTM E 455
|
Static Load Testing of Floor or Roof Diaphragm Constructions for Buildings
|
ASTM E 529
|
Conducting Flexural Tests on Beams and Girders for Building Construction
|
ASTM E 547
|
Water Penetration Resistance of Exterior Doors by Cyclic Static Air Pressure Differential
|
ASTM E 564
|
Static Load Test for Shear Resistance of Framed Walls for Buildings
|
ASTM E 576
|
Frost Point of Sealed Insulating Glass Units
|
ASTM E 72
|
Strength Test of Panels for Building Construction
|
ASTM E 73
|
Static Load Testing of Truss Assemblies
|
ASTM E 773
|
Accelerated Weathering of Sealed Insulating Glass Units
|
ASTM E 779
|
Determining Air Leakage Rate by Fan Depressurization
|
ASTM E 783
|
Field Measurement of Air Leakage Through Installed Exterior Windows and Doors
|
ASTM E 894
|
Anchorage of Permanent Metal Railing Systems and Rails for Buildings
|
ASTM E 907
|
Field Testing Uplift Resistance of Adhered Membrane Roofing Systems
|
ASTM E 935
|
Performance of Permanent Metal Railing Systems and Rails for Buildings
|
ASTM E 936
|
Inspection of Roof Systems Assemblies Employing Steel Deck, Preformed Roof Insulation, and Bituminous Built-up Roofing
|
ASTM E 96
|
Standard Test Methods for Water Vapour Transmission of Materials
|
ASTM E 987
|
Standard Test Methods for Deglazing Force of Fenestration Products
|
ASTM E 997
|
Structural Performance of Glass in Exterior Windows, Curtain Walls and Doors Under the Influence of Uniform Static Loads by Destructive Methods
|
ASTM E 998
|
Structural Performance of Glass in Exterior Windows, Curtain Walls and Doors Under the Influence of Uniform Static Loads by Nondestructive Methods
|
ASTM E2178
|
Standard Test Method for Air Permeance of Building Materials
|
ASTM E2188
|
Standard Test Method for Insulating Glass Unit Performance
|
ASTM E2189
|
Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units
|
ASTM E2190
|
Standard Specification for Insulating Glass Unit Performance and Evaluation
|
ASTM E2273
|
Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies
|
ASTM F 1233
|
Resistance to Forced Entry of Security Glazing Systems, Non Ballistic Testing Only
|
ASTM F 476
|
Resistance to Forced Entry of Swinging Door Assemblies
|
ASTM F 588
|
Resistance to Forced Entry of Window Assemblies
|
ASTM F 842
|
Resistance to Forced Entry of Horizontal Sliding Door Assemblies
|
ASTM G 155
|
Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials
|
CAN BEST TM N104
|
Prefabricated Masonry Panels Performance Evaluation, Masterformat Section 04840
|
CAN BEST TM N105
|
Manufactured Steel Building Performance Evaluation, Masterformat Section 05401
|
CAN BEST TM N106
|
Prefabricated Insulated Steel Panel System Performance Evaluation, Masterformat Section 05405
|
CAN BEST TM N107
|
Open Web steel Frame Housing and Small Building Performance Evaluation, Masterformat Section 05403
|
CAN BEST TM N108
|
Structural Panels Performance Evaluation, Masterformat Section 06120
|
CAN BEST TM N109
|
Prefabricated Structural Wood Performance Evaluation, Masterformat Section 06170
|
CAN BEST TM N110
|
Wall Panel System Performance Evaluation, Masterformat Section 06300
|
CAN BEST TM N111
|
Exterior Insulation and Finish Panels EIFS (Thin Rendering) Performance Evaluation, Masterformat Section 07240
|
CAN BEST TM N112
|
Exterior Insulation and Finish Panels EIFS (Other Finishes) Performance Evaluation, Masterformat Section 07250
|
CAN BEST TM N113
|
Exterior Cement Board and Finish System Performance Evaluation, Masterformat Section 07255
|
CAN BEST TM N114
|
Vapour Retarders Performance Evaluation, Masterformat Section 07260
|
CAN BEST TM N115
|
Air Barriers Performance Evaluation, Masterformat Section 07270
|
CAN BEST TM N116
|
Metal Roof and Wall Panels Performance Evaluation, Masterformat Section 07410
|
CAN BEST TM N117
|
Plastic Roof and Wall Panels Performance Evaluation, Masterformat Section 07420
|
CAN BEST TM N118
|
Asphalt Corrugated Roof Panels Performance Evaluation, Masterformat Section 07425
|
CAN BEST TM N119
|
Composite Panels Performance Evaluation, Masterformat Section 07430
|
CAN BEST TM N120
|
Exterior Wall Assemblies Performance Evaluation, Masterformat Section 07430
|
CAN/CGSB-63.14
|
Skylights, Plastic
|
CAN/CGSB-82.1
|
Doors, Sliding
|
CAN/CGSB-82.5
|
Doors, Insulated Steel
|
CAN-BEST TM N101
|
Pressure Equalization Performance of Wall Assemblies Under Natural or Simulated Wind Conditions, Field and Laboratory Evaluation
|
CAN-BEST TM N102
|
Field Evaluation of Pressure Equalization Performance of Wall Assemblies Under Natural Wind Conditons
|
CAN-BEST TM N103
|
Field Evaluation of Pressure Equalization Performance of Wall Assemblies Subjected to Applied Pressure Differential
|
CAN-BEST TM N121
|
Method for Rating Water Vapour Transmission (Double Cup and Modified Inverted Cup Methods)
|
CAN-BEST TM N122
|
Method for Field Evaluation of Air Leakage in Building Envelope
|
CGSB 82-GP-3M
|
Door, Aluminum, Combination Storm and Screen
|
CGSB 82-GP-4M
|
Door, Steel, Combination Storm and Screen
|
CGSB CAN2-12.1
|
Glass, Safety, Tempered or Laminated
|
CGSB CAN2-12.2
|
Glass, Sheet, Flat, Clear
|
CGSB CAN2-12.8
|
Insulating Glass Units
|
CGSB CAN2-12.9
|
Glass, Spandrel
|
CSA A-440
|
Windows
|
CSA A-440.2
|
Energy Performance Evaluation of Windows and Sliding Glass Doors
|